Building Automation Protocol selecting

Building Automation Protocol selecting

Each of the competing protocols claims to be the best. So how do facility executives select the one that is best suited for the facility?

Data is communicated between devices through a Communication Protocol. It is the language that a particular device is able to interpret and forward to other devices on the network. Some common protocols are BACnet, Lon, and Modbus.

Protocols must be selected based on the needs of the facility and its ability to support a particular protocol. Each has been used many times to implement an interoperable system. Each has its advantages and disadvantages. Involve your information technology department. They generally are the controlling agency for the facility’s network infrastructure.


When selecting a control system choose one where the front end is compatible with a number of protocols. This will give greater flexibility as building equipment and devices change over time.

Why you want a BMS with open protocols
A BMS with proprietary protocols locks the system owner into using a single BMS vendor. For example, you can’t remotely change the set points of a proprietary BMS unless you use the vendor’s software.
In contrast, with open and standard BMS protocols you can shop for alternative providers of digital devices and enterprise software.

Building Automation Controls Network (BACnet): BACnet is a network protocol specifically used for multiple devices to communicate across building automation systems by system users and building system manufacturers

Modbus: Modbus is a network protocol best used for industrial automation systems specifically for connecting electronic equipment. Although Modbus is best for industrial applications, its simplicity allows it to be a useful tool for building automation as well.


LonWorks: LonWorks is a communication network protocol useful for building automation applications designed on a low bandwidth, for networking devices through power lines, fiber optics, and other media.

Protocol
BACnet
Modbus
LonWorks
Full Name
Building Automation Controls
Serial Communication Protocol
Local Operational Networks
Developed By:
ASHRAE
Modicon Inc.
Echelon Corporation/ Motorola
Use
Communication across devices
Connection between devices
Networking devices through power lines, fiber optics, and other media
Markets
Industrial, Transportation, Energy Management, Building Automation, Regulatory and health and safety
HVAC, Lighting, Life Safety, Access Controls, transportation and maintenance
Home automation, industrial, transportation, and public utility control networks.
Examples
Boiler Control, Tank Level Measurements
Tasks such as request temperature reading, send status alarm, or fan schedule
Security, lighting systems, HVAC, machine control, manufacturing, metering
Proprietary
No
No
Yes
Transmission Modes
Ethernet, IP, MS/TP, Zigbee
ASCII, RTU, TCP/IP
MS/TP, network, SNVT
Standards
ANSI/ASHRAE Standard 185 ;ISO-16484-5; ISO-16484-6
IEC 61158 
ANSI/EIA 709.1; ISO/IEC 14908-1, 14908-2, 14908-3, 14908-4
Costs
Low; No charge for usage or licensing fees
Low; No charge for usage or licensing fees
High (proprietary); Limited users (exclusive to actual members;  mostly manufacturers)
Network Interfaces
Existing LANs and LANs infrastructure
Traditional serial and Ethernet protocols
U10/U20 USB Network Interface; i.LON SmartServer; i.LON 600
Testing
BACnet Testing Labs
Modbus TCP Conformance Testing Program
Products must  conform to LonWorks protocol
Advantages
- Scalability between cost, performance and system size
- Easy connection to Modicon
- Web based tool; saves time and cost
- Endorsement and adoption by nearly every major vendor in North America and many other countries
- Suitable for small/medium volumes of data (≤255 bytes)
- Numerous developers of LonWorks products in the market
- Robust internetworking including multiple LAN types and dial-up
- Data transfer designed for industrial applications
- Less Architecture at device level
- Unrestricted growth and the ability to add new innovations and new features anytime
- Openly published and royalty-free


- Easy to deploy and maintain


- Moves raw bits or words without placing restrictions on vendors

Disadvantages
- Limited the number of field devices that can connect to a master station except Ethernet TCP/IP
- Limited the number of data types; Large binary objects are not supported.
- Outdated
- MT/TP-Wire Length
- No standard method for a node to find the description of a data object, i.e. finding a register value represents a temperature between 30◦ and 175◦.
- Controlled devices & variables are connected to a separate control device. (Not recommended due to network interruptions producing system failures)
- Ethernet-Infrastructure
- No security against unauthorized commands or interception of data
- Extensions are allowed only through the LonMark Consortium.
- New standard has security standard but not implemented in all devices
- Transmissions must be contiguous which limits the types of remote communications devices to those that can buffer data to avoid gaps in the transmission.
- Hardware specific, and requires the Neuron chip for network movement of the protocol.

- Great amount of configuration and programming required
- Close to “plug & play” ability, yet still far from achieving interconnectivity using Microsoft Windows.

- Protocol is not common in the SIMATIC family


To determine whether a BMS protocol is open, ask the vendor two simple questions:
1.     Can your competitors exchange data with your BMS?
2.     Is the system’s protocol published in such a way that it’s easily accessible to everyone (including competitors)?



Even the ASHRAE BACNet committee has convened a working group to define use of XML with BACnet systems. The group is also working to define web services that will enable data exchange between building automation and control systems and various enterprise management systems.

Use these criteria when you’re choosing devices and BMS:
1.     For devices such as RTUs and refrigeration controllers, look for ones that use open protocols such as BACnet or Modbus.
2.     Make sure these devices give you both “read” and “write” capabilities so you can change set points.
3.     For easy enterprise access, choose a BMS with web services and XML capabilities.
4.     Make sure the web services of the BMS allow both read and write capabilities.
5.     Be sure the BMS supplier provides the XML dictionary and definitions of web services to anyone, including competitors.



Thursday, September 3, 2015

About PSIM

What is PSIM?

PSIM stands for Physical Security Information Management, however it certainly requires further explanation about why it is important. Firstly, the future of all security systems is IP based, this means that CCTV, Access Control, Intruder and Fire Alarms will be computer based. Analogue and standalone systems are becoming more redundant and technology is moving rapidly towards converging all these IP based systems onto a single software management platform.
Assuming your security systems are IP based, then PSIM software packages will make an incredible difference to way you secure your school, business or public sector space. This means facility or building management staff can centralise all systems onto a single platform and remotely manage the building.
The key attributes of a PSIM system are:
1. Collection: Device management independent software collects data from any number of disparate security devices or systems
2. Analysis: The system analyses and correlates the data, events, and alarms, to identify the real situations and their priority
3. Verification: PSIM software presents the relevant situation information in a quick and easily-digestible format for an operator to verify the situation
4. Resolution: The system provides Standard Operating Procedures (SOPs), step-by-step instructions based on best practices and an organisation’s policies, and tools to resolve the situation
5. Reporting: The PSIM software tracks all the information and steps for compliance reporting, training and potentially, in-depth investigative analysis
6. Audit trail: The PSIM also monitors how each operator interacts with the system, tracks any manual changes to security systems and calculates reaction times for each event
PSIM is considered essential for Control Rooms or Command and Control Operations, as the software, provided all the systems are IP based, converge all the disparate systems onto a single platform to provide full management. Common security systems integrated onto a PSIM platform are:

- IP Access control systems
- IP CCTV systems
- Fire detection
- Video wall
- Intrusion detection systems
- Perimeter Intrusion detection systems
- Radar based detections
- GIS mapping systems
- Intercom or IP Phone systems
- Automated barriers & bollards
- Building management systems


The aggregated data, information and footage from the various systems provides the operator with intelligence to effectively manage situations (i.e fires, intruders etc) or day to day management of the building (i.e remote door locking etc). Ultimately, this means the need for large teams of facility staff can be reduce and the building managed centrally by key operators. A key reason for the development of PSIM has been the technology improvements of the systems listed above, which has meant software developers have been able to integrate and converge these systems onto single platforms. Technology in security systems is improving dramatically, prices are falling for systems and the software required to manage them is now available. It really makes sense to move forward and use PSIM to its full potential, let Sunstone help you embrace the future.